Mica Band Heaters Mica Band Heaters Mica Band Heaters
 
Mica Band Heaters
 

Mica Band Heaters - Installation Tips

  • The cylinder should be clean from any contaminants and foreign materials
  • The heater should be tightened firmly on the cylinder. The rims should be gently tapped with a plastic mallet and the heater re-tightened

  • Energize the heater for a short period of time and then re-tighten the fasteners

  • To compensate for thermal expansion, large diameter heaters should have spring loaded fasteners

  • Tone piece construction heaters should be opened only slightly, and made to slide on a cylinder. Two piece construction or flexible heaters should be used when a heater has to be fully opened