Hot Runner Systems - Description
The Hot Runner System control
modules are fully automatic PID controllers with on board diagnostics
for Open, Shorted, or Reversed thermocouple.
The Hot Runner System also features LED's for under temperature or
over temperature indication, Heat load on/off, Ramp start, and Open or
closed loop operation. The display can also be set for set point or
process temperature indication and a +/- 3 degree indicator flashes
when process temperature is within 3 degrees of setpoint.
Hot Runner System control modules are also designed for full
communication capability with alarm and standby module.
Hot Runner System Features:
-
Microprocessor based controllers
-
Automatic tuning PID Control
-
Touch pad front panel controls
-
Soft start ramp up standard
feature
-
Auto or manual mode available
thermocouple status indicator
-
Current indication setpoint or
process indication
-
Under/over temperature indication
Hot Runner System Specifications:
Voltage. . . . . . . . . . . . . .
. .120 or 240 volts
Output Current/ Watts. . . . .15 amps 3600 watts at 240 1800 at 120
Input. . . . . . . . . . . . . . . . . .Type J thermocouple Grounded or
ungrounded
T/C Break protection. . . . . . Inhibits power to heater
Control Accuracy. . . . . . . . +/-1ºF or +/- .5ºC
Temperature Range. . . . . . .Ambient to 999ºF (535ºC)
Cycle time. . . . . . . . . . . . . 0.33 seconds
Manual control. . . . . . . . . . Adjustable from 0 to 100%
Ramp Start. . . . . . . . . . . . .Duration 5 minutes
Output. . . . . . . . . . . . . . . . Zero cross triac triggering
Data Communication. . . . . .IBM PC compatible
Compatibility. . . . . . . . . . . .Hot runner industrial standard
compatible
Accessories. . . . . . . . . . . . 600 to 240 volts step down transformers
Power connectors 5, 8,12, zones
Thermocouple connectors 5, 8,12 zones
Floor Stands will support up to 48 zones
Main Frames 5, 8,12, Stackable to 48 zones
|