Heat Calculation Considerations and Equations"Calculations determine the amount of heater wattage required for process startup and process operation" CONSIDERATIONS FOR PROCESS STARTUP:
III. EQUATIONS FOR ADDITIONAL WATTAGE REQUIREMENTS ADDITIONAL HEATUP REQUIREMENTS (IF APPLICABLE): 2. Wattage req'd to heat container or tank (if applicable):
3. Wattage required to heat hardware in container (if applicable): calculation similar to #1 and #2 = watts 4. Wattage required to melt a solid to a liquid (if applicable) at constant temperature:
5. Wattage required to change a liquid to a vapor state at constant temperature (if applicable):
Heats of fusion (solid to liquid) and vaporization (liquid to gas) are the heat energy required to change a lb. of the material from state to state at constant temperature. 6. Wattage to counteract liquid surface losses (if applicable) See Graph for loss rate of materials:
7. Wattage to counteract losses from container walls, platen surfaces, etc. See Graph for losses from surfaces:
IV. OPERATING WATTAGE REQUIREMENTS Operating requirements should include some or all of the following plus some miscellaneous losses which should be estimated and included: 1. Wattage to counteract losses from open liquid surfaces: (See graph for loss rates of water and oils) Total liquid surface area (sq. ft.) x loss rate at operating temperature (watts/sq. ft.) = operating wattage losses 2. Wattage to counteract container or platen surface losses, (See graphs for loss rates) Total liquid surface area (sq. ft.) x loss rate at operating temperature (watts/sq. ft.) = operating wattage losses 3. Wattage required to heat material transferred in and out of the system (Metal dipped in heated tanks, air flows, make-up liquids, etc.)
4. Heatup of racks or containers, etc. transferred in and out of the system:
5. Melting or vaporization of material requirements should also be included if applicable. Drying, or evaporation, requires use of the heat of vaporization.
|
||||||||||||||||||||||||||||||||||
| |
|||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||